SIGNET PDA-200-2 ringleiding versterker

475.00

Categorie:

Beschrijving

PDA200-2 MK2 / 200M? pro ringleiding versterkerversterker Apparaat wat kleine signalen versterkt tot hoog speakernivo  met XLR mic/line in

Alle ringleiding materiaal wordt speciaal besteld en u heeft geen teruggaaf recht op deze artikelen.


 

SigNET PDA200/2 professional current mode audio-frequency
induction Afils loop amplifiers offer outstanding sound quality at a
competitive price.Helping deaf hearing aid users.

They are ideal for use in large prestigious applications such as
theatres, churches, cathedrals, cinemas, large conference halls, etc.,
where first class sound and unrivalled reliability are a must.

Each amplifier includes one balanced microphone input and one
switchable balanced mic. or line level input, both of which will accept
standard 3 pin XLR connectors. Optional 11V phantom power is also
available on both inputs to allow the use of electret or condenser
microphones.

By popular demand, each amplifier also features a four-way
?Outreach? input offering full compatibility with SigNET?s unique
Outreach Plate audio input extension system. This system allows the
connection of up to 10 additional microphone or line level inputs via a
range of specially designed single gang connector plates.

The pre-amplification stage of each amplifier utilises an advanced
signal processing system that allows tight control over the audio
signal without any degradation of output quality. A metal compensation
control is also provided to help offset the frequency response problems
associated with excessive metal content of some rooms.

Other features include three level controls (one for each input), a
loop drive control, an output current meter and a ?compression?
activity display giving visible indication of the amplifier?s
compressor.

Audio-frequency induction loop systems work by transmitting
amplified sound to hearing aids. Most hearing aids have a ?T? or ?MT?
switch which allows them to pick up the electromagnetic field generated
by an induction loop system. The hearing aid converts this signal to a
sound suited to its user?s specific hearing requirements, allowing them
to participate more fully in general conversation, ordering goods or
services, etc.

  • Two XLR 3 pin input sockets – one balanced mic. and one switchable balanced mic./line
  • Optional 11V phantom power available for electret or condenser microphones
  • Outreach input allows the connection ofup to 10 additional mic. or
    line level inputs via a series of separately
    available single gang connector plates
  • Adjustable level controls provided for all inputs – can be used
    individually or together as a three-&nbsp input
    mixer.
  • Adjustable drive control allows the loop current to be adjusted to
    suit a rooms individual characteristics
  • Metal compensation control helps offset the frequency response
    problems associated with excessive metal in a
    building.
  • True output current meter
  • Visible indication of the amplifiers compressor action via two LEDs
  • 3.5mm headphone socket allows true monitoring of the output signal
  • Advanced audio signal processing with automatic gain control (AGC)
  • On-board cooling fan on PDA500/2 and PDA1000/2 promotes stable
    operating temperature and increased reliability
  • All models designed to meet or exceed the requirements of BS7594
    and EN60118-4 when correctly installed
  • Power – 230-240 V a.c. mains (PDA200/2 <150 VA; PDA500/2 <225
    VA; PDA1000/2 <300 VA). IEC 320 fused mains lead supplied)
  • Inputs – Line (3 pin XLR) – impedance: 6k8 + or – input to ground;
    Sensitivity: 200mV 2.5V RMS balanced or unbalanced. Microphones (3 pin
    XLR) – impedance: 6k8 + or – input to ground; Sensitivity: 1- 8 mV
    balanced Phantom power: 12V switchable (on/off) Outreach (Four-way
    Weidmuller connector BL5. 08/4) – impedance: >10k; Sensitivity:
    500mV – 6V RMS balanced Outreach Power: 16 – 21 V d.c. is available via
    the amplifiers Outreach Socket.
  • Output type – Current mode
  • Loop connector – Four way binding posts
  • Recommended loop impedance: 0.5 – 1 Ohm @ 1KHz. Will drive higher impedance loops with reduced area of coverage.
  • Loop drive current @ 1 Ohm: PDA200/2 – 6A; PDA500/2 – 9A; PDA1000/2 – 12A.
  • Peak loop drive current (Measured over 5mS integration time) –
    PDA200/2 – 8 Amps @ 1 Ohm, 13Amps @ 0.5 Ohm; PDA500/2 – 12 Amps @ 1
    Ohm, 19 Amps @ 0.5 Ohm; PDA1000/2 – 14 Amps @ 1 Ohm, 24 Amps @ 0.5 Ohm
  • Recommended cable gauge: See Loop Cable Selection Graph (above).
  • Headphones: 3.5mm jack socket allows monitoring of the loop signal via >32 Ohm headphones.
  • Maximum area coverage: For a 400mA/M field strength +/- 1dB.
    PDA200/2 @ 6A max short term current: Square room = 200m2; Rectangular
    room (2:1 aspect ratio) = 240m2 PDA500/2 @ 9A max short term current:
    Square room = 500m2; Rectangular room (2:1 aspect ratio) = 600m2
    PDA1000/2 @ 12A max short term current: Square room = 900m2;
    Rectangular room (2:1 aspect ratio) = 1100m2
  • Performance Frequency response: 20Hz – 14 KHz + – 3dB; Distortion: Less than 0.5 %; S to N ratio: Better than -65dB any input
  • Compressor: Gives dynamically variable compression ratio from 1:1
    (no compression) to 17:1 Attack time: Approx. 10mS. Release time:
    Approx. 2.2S Metal Compensation: True 3dB /octave design counteracts
    frequency dependent absorption by metal in the proximity of the
    installation over a bandwidth of approximately 100Hz – 10KHz.
  • Indicators – Power on LED: Red Loop current: A five LED bar graph
    type meter is provided to allow monitoring of loop current output and
    assist in setting up the amplifier. This is provided by monitoring true
    output current rather than from a line level derived signal. This meter
    has PPM type characteristics i.e. fast attack and slow release. This
    allows easy reading of fast peaks. Accuracy – +-10% Compression: A two
    LED display is provided for indication of signal compression. The first
    LED shows the beginning of compression whilst the second indicates very
    high compression levels have been reached.
  • Controls – On/Off switch incorporated into IEC mains inlet. Four
    way piano key style DIP switch selects Phantom power for mic 1 & 2
    XLR inputs and switches XLR input 1 between Line and Microphone
    settings. The fourth of the 4-in-line switch is not connected. Level
    controls for XLR 1 (Line/Mic switchable), XLR 2 (Mic) and Outreach.
    These can be used individually or any of them together, in which case
    they act as a three input mixer. Drive control: Sets the level of
    amplifier output current supplied by the amplifier. Metal compensation
    control. When fully anti-clockwise has no effect on the signal. When
    turned clockwise imparts a rising 3dB/octave characteristic to the
    frequency response of the amp to counteract the effect of metal in
    proximity to the loop.
  • Cooling Requirements – The PDA1000/2 and PDA500/2 have
    thermostatically controlled cooling fans, which are activated when the
    amplifiers internal heatsink temperature reaches approxi. 56oC. The
    PDA200/2 model does not require a cooling fan, as it does not generate
    as much heat as the larger models.
  • Dimensions – All models: Length – 380mm; Depth – 220mm; Height – 80mm
  • Weight – PDA200/2 – 3.74Kg, PDA500/2 – 3.46Kg; PDA1000/2 – 4.54Kg